Power your research with expert solutions and reliable results.
Research Services

Pre-made Library Sequencing

Introduction to Pre-made Library Sequencing

With advanced sequencing platforms from Illumina, Element Biosciences, and PacBio, Novogene provides high-quality sequencing-only services for customer-prepared libraries. Projects can be configured across multiple read lengths and data scales to balance turnaround time, cost, and desired coverage depth.

Customers simply submit their premade libraries, and our laboratories handle sequencing and data generation with precision. Supported platforms include the Illumina NovaSeq series (SP, 10B, 25B flow cells with both partial- and full-lane options), Element AVITI24™ for flexible short-read sequencing, and PacBio Revio for complete SMRT-cell long-read analysis.

Our experienced technical and operations teams ensure rigorous quality control, rapid delivery, and dependable performance. By combining global capacity with local expertise, Novogene delivers fast, reliable sequencing data at competitive pricing: helping researchers move efficiently from libraries to results.

Benefits of Pre-made Library Sequencing

  • Cutting-edge technology. Novogene combines advanced platforms such as Illumina NovaSeq X Plus, Element AVITI24™, and PacBio Revio to deliver high-precision sequencing across short- and long-read applications.
  • Flexible sequencing strategies. We offer a wide range of read configurations—SE50, PE50, PE75, PE150, PE250, PE300, and HiFi long reads—alongside customised strategies for projects requiring specific coverage depth, insert size, or workflow adaptation.
  • Proven expertise. With thousands of projects completed worldwide, Novogene’s data have supported publications in top journals including Cell, Nature, and Science. Our experienced teams ensure every run meets the highest standards of accuracy and consistency.
  • Rapid turnaround. Our laboratories in Germany and the UK shorten delivery times and simplify logistics. Combined with high-throughput capacity and automated workflows, this enables fast, reliable sequencing without compromising data quality.

Pre-made Library Sequencing Specifications: Short-read libraries sample requirements

Platform Data amount Volume Requirement Library Concentration
NovaSeq X Plus PE150 <30 Gb ≥15 μL ≥ 2 ng/μL, quantified by Qubit® 2.0 (Life Technologies)
≥2 nM, quantified by qPCR
30 Gb ≤ X < 100 Gb ≥ 30 μL
100 Gb ≤ X < 375 Gb ≥70 μL
375 Gb ≤ X < 1 Tb ≥130 μL
Lane sequencing on 10B ≥70 μL (additional 70 μL for one more lane)
Lane sequencing on 25B ≥130 μL (additional 130 μL for one more lane)
NovaSeq series SE50/PE50/PE250
&
AVITI24 SE50/PE50/PE75/PE150 or PE300
<20 M reads ≥15 μL
20 M reads ≤ X < 50 M reads ≥25 μL
50 M reads ≤ X ≤ 150 M reads ≥50 μL
Lane sequencing ≥70 μL (additional 70 μL for one more lane)

Notes: High concentration samples should be diluted before delivery. Pre-made libraries should be colourless. Click here to view the complete details of our sample requirements.

On-demand Webinar

Enhancing NGS Applications: Exploring Novogene’s Pre-made Library Sequencing Service and Illumina’s NovaSeq™ X Plus System

In this webinar, we will provide an overview of Novogene’s pre-made library sequencing service and introduce the Illumina NovaSeq X Plus system. We will discuss the workflow and considerations for successful library preparation and highlight the key features of the NovaSeq X Plus that are designed to streamline the sequencing process and improve data output.

The overview of the NovaSeq X Plus system and its features will be presented by a special guest speaker from Illumina, offering a unique opportunity to gain insights directly from the source.

Learning Objectives:

  • Introduction to Illumina sequencing technology
  • Library preparation workflow and considerations
  • Pre-made library sequencing service by Novogene
  • Overview of the NovaSeq X Plus system and its features
  • NovaSeq X Plus-based services offered by Novogene.

Illumina Sequencing Outputs

 

Platform Read Length Output*
NovaSeq X Plus PE150 10B flow cell
375 Gb/lane
3 Tb/flow cell
25B flow cell
1 Tb/lane
8 Tb/flow cell
SE50 1.5B flow cell
38Gb/lane
75 Gb/flow cell
PE50 1.5B flow cell
75 Gb/lane
150 Gb/flow cell
NovaSeq 6000 PE250 200 Gb/lane
400 Gb/flow cell

*Note: The above outputs vary depending on factors such as the quality of the sequencing library, library type, insert size, etc.
We also offer custom options, such as adjustable read lengths to suit your specific project needs. Contact us to explore these options and discuss how we can tailor our services to meet your research goals.

PacBio Sequencing Output

 

Platform Read Length Output*
Revio 15–20 kb Up to 90 Gb/SMRT Cell

*Note: The above outputs vary depending on factors such as the quality of the sequencing library, library type, insert size, etc. 

Novogene Workflow of Pre-made Library Sequencing

 
For self-constructed libraries provided by the customers, quality control analysis is performed before sequencing to ensure the quality of the data. The qualified libraries are then pooled based on their effective concentrations and expected data volumes, followed by sequencing using Illumina, Element Biosciences or PacBio platforms.